United States set
language
Menu Shopping cart $0 Search
Manufactured by BioVendor

Recombinant Factor C Endotoxin Detection Kit

  • Regulatory status:RUO
United States orders are shipped from our US branch, BioVendor, LLC
Cat. No. Size Price


RZA001R 96 tests (1 kit)
Product Details
Technical Data

Sample Requirements

100 µl/well

Storage/Expiration

Store the complete kit at 2 - 8 °C. Under these conditions, all components are stable until the expiration date (see label on the box). High stability of endotoxin standard after reconstitution: endotoxin standard can be stored at 4℃ for 8 weeks after reconstitution.

Calibration Range

0,005 - 5 EU/ml

Limit of Detection

less than 0,005 EU/ml

Intra-assay (Within-Run)

less than CV =5%

Inter-assay (Run-to-Run)

less than CV =10%

Summary

Features

  • It is intended for research use only.
  • Recombinant Factor C Endotoxin Detection Kit is intended for in vitro quantitative determination of lipopolysaccharide (LPS) in aqueous samples and biological fluids in non-regulated fields.
  • Recombinant Factor C Endotoxin Detection Kit is not intended for the diagnosis of human or animal diseases and is not suitable for the detection of endotoxin in serum, plasma and blood samples.
  • Two-point end-point fluorescence assay
  • High sensitive assay
  • No washing step
  • Robust assay with excellent reproducibility, high stability of endotoxin standard after reconstitution
  • Broad measurement range (0.005–5 EU/ml)
  • pH range (pH6 – pH8), excitation/emission wavelength of 380/440nm
  • All reagents necessary to run the assay included in the kit
  • Uses recombinant Factor C (rFC), thus saving the diminishing horseshoe crab population

Summary

The BioVendor Recombinant C Factor (rFC) Endotoxin Detection Kit is based on a fluorescence enzymatic reaction using recombinant Factor C.

Assay principle:

The kit contains recombinant Factor C, a genetically engineered protein that specifically recognizes endotoxins (lipopolysaccharides, LPS) from Gram-negative bacteria. If endotoxin is present in the sample, it binds to and activates recombinant Factor C. The activated Factor C cleaves a fluorogenic substrate included in the kitresulting in a fluorescent signal. The fluorescence intensity is directly proportional to the endotoxin concentration and is quantified using a calibration curve.

Docs
Subscribe to Our Newsletter! Discover News from
BioVendor R&D
Subscribe Now
Subscribe to Our Newsletter! Discover News from
BioVendor R&D
Subscribe Now
zavřít